beautypg.com

Ibm rpq settings – Xerox 3270 User Manual

Page 24

background image

3270 Programmer’s Guide
IBM Related Functions

- 24 -

NOTE:
If the converter
is connected directly to an IBM 4331
or 4361, the buffer size of 1920 characters (Function
Y1=2) should be specified, due to a hard

ware

restriction on the mainframe.

4.3. IBM RPQ Settings

The Functions 25 to 33 are similar to the RPQs you can order for an
IBM 3287 or IBM 3268 printer as shown in the following table. On the
IBM 4214, you may set the options from the front panel.

The charts below show the correspondence between interface
functions and IBM RPQ numbers.

Function no. 3287 RPQs

3268 RPQs

4214 RPQs

25

N/A

*)

N/A

N/A

26

SC3750

SC9508

Opt. 20=3

27

SC3741

SC9505

Opt. 18=3

28

S30219

SC9501

Opt. 15=1

29

S30219

SC9502

Opt. 15=1

30

N/A

SC9503

Opt. 16=2

31

SC3749

SC9504

Opt. 17=2

32

SC3739

SC9506

Opt. 19=1

33

SC3740

SC9507

Opt. 20=2

*) N/A: Not Applicable

Function no. 4028 RPQs

3812/16 RPQs

3912/16 RPQs

25

N/A

*)

N/A

N/A

26

Set. 25

Switch C16

27

Set 31

Switch C22

PrintImage

28

Set. 27

Swtich C18

CR at MPP+1

29

Set. 28

Switch C19

NL at MPP+1

30

Set. 29

Switch C20

FF Data

31

Set. 30

Switch C21

FF Last

32

Set. 32

Switch C23

FF Valid

33

Set. 33

Switch C24

Auto Function

*) N/A: Not Applicable