beautypg.com

Midi data format – Yamaha PLG100-XG User Manual

Page 34

background image

34

MIDI Data Format

nn = PART NUMBER

In the case of a DRUM PART, the following parameters will have no effect.

• BANK SELECT LSB
• MONO/POLY MODE
• SCALE TUNING
• PORTAMENTO
• PITCH EG

< Table 1-5 >

MIDI Parameter Change table ( DRUM SETUP )

Address

Size

Data

Parameter

Description

Default value

(H)

(H)

(H)

(H)

3n rr

00

1

00 - 7F

PITCH COARSE

-64...0...+63

40

01

1

00 - 7F

PITCH FINE

-64...0...+63[cent]

40

02

1

00 - 7F

LEVEL

0...127

depend on the note

03

1

00 - 7F

ALTERNATE GROUP

OFF,1...127

depend on the note

04

1

00 - 7F

PAN

RND,L63...C...R63

depend on the note

05

1

00 - 7F

REVERB SEND

0...127

depend on the note

06

1

00 - 7F

CHORUS SEND

0...127

depend on the note

07

1

00 - 7F

VARIATION SEND

0...127

7F

08

1

00 - 01

KEY ASSIGN

SINGLE , MULTI

00

09

1

00 - 01

Rcv NOTE OFF

OFF , ON

depend on the note

0A

1

00 - 01

Rcv NOTE ON

OFF , ON

01

0B

1

00 - 7F

LOW PASS FILTER CUTOFF FREQUENCY

-64...0...63

40

0C

1

00 - 7F

LOW PASS FILTER RESONANCE

-64...0...63

40

0D

1

00 - 7F

EG ATTACK RATE

-64...0...63

40

0E

1

00 - 7F

EG DECAY1 RATE

-64...0...63

40

0F

1

00 - 7F

EG DECAY2 RATE

-64...0...63

40

TOTAL SIZE

10

n:Drum Setup Number(0 - 1)
rr:note number(0D - 5B)

In the following cases, all Drum Setups will be initialized.

XG SYSTEM ON received
GM SYSTEM ON received
DRUM SETUP RESET received (only setup applies)

[Note]
When a part to which a Drum Setup is assigned receives a program change, the assigned Drum Setup will be initialized.
If the same Drum Setup is assigned to two or more parts, changes in Drum Setup parameters (including program changes)will apply to all parts to which it is assigned.