York THGD18 THRU 60 User Manual
Page 12

365147-YTG-C-0608
12
Johnson Controls Unitary Products
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by
the total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils
UNIT
MODEL*
COIL
1
MODEL
ARI HEATING
2
47
°F
17
°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
THGD18S21S1
FC/MC/PC/UC18
17.0 3.26 1.54 9.0 2.18 1.23 7.70
FC/MC/PC/UC24
17.0 3.26 1.54 9.0 2.18 1.23 7.70
FC/MC/PC/UC30
17.0 3.26 1.54 9.0 2.18 1.23 7.70
HC18
17.0 3.26 1.54 9.0 2.18 1.23 7.70
THGD24S21S1
FC/MC/PC/UC24
23.0 3.72 1.82 12.0 2.44 1.47 7.70
FC/MC/PC/UC30
23.0 3.72 1.82 12.0 2.44 1.47 7.70
FC/MC/PC/UC32
23.0 3.72 1.82 12.0 2.44 1.47 7.70
FC/MC/PC/UC35
23.0 3.72 1.82 12.0 2.44 1.47 7.70
HC30
23.0 3.72 1.82 12.0 2.44 1.47 7.70
HC36
23.0 3.72 1.82 12.0 2.44 1.47 7.70
HD24
23.0 3.72 1.82 12.0 2.44 1.47 7.70
MH24S
23.0 3.72 1.82 12.0 2.44 1.47 7.70
MH30S
23.0 3.72 1.82 12.0 2.44 1.47 7.70
THGD30S21S1
FC/MC/PC/UC32
29.0 3.56 2.40 15.0 2.24 1.96 7.70
FC/MC/PC/UC35
29.0 3.56 2.40 15.0 2.24 1.96 7.70
FC/MC/PC/UC37
29.0 3.56 2.40 15.0 2.24 1.96 7.70
FC/MC/PC/UC43
29.0 3.56 2.40 15.0 2.24 1.96 7.70
HC36
29.0 3.56 2.40 15.0 2.24 1.96 7.70
HC42
29.0 3.56 2.40 15.0 2.24 1.96 7.70
HD36
29.0 3.56 2.40 15.0 2.24 1.96 7.70
MH24S
29.0 3.56 2.40 15.0 2.24 1.96 7.70
MH30S
29.0 3.56 2.40 15.0 2.24 1.96 7.70
THGD36S21S1
FC/MC/PC/UC37
34.0 3.58 2.78 21.0 2.52 2.39 8.50
FC/MC/PC/UC43
34.0 3.58 2.78 21.0 2.52 2.39 8.50
FC/MC/PC/UC48
34.0 3.58 2.78 21.0 2.52 2.39 8.50
FC/MC/PC/UC60
34.0 3.58 2.78 21.0 2.52 2.39 8.50
HC42
34.0 3.58 2.78 21.0 2.52 2.39 8.50
HC60
34.0 3.58 2.78 21.0 2.52 2.39 8.50
HD48
34.0 3.58 2.78 21.0 2.52 2.39 8.50
HD60
34.0 3.58 2.78 21.0 2.52 2.39 8.50
THGD42S21S1
FC/MC/PC/UC48
42.0 3.52 3.45 25.0 2.60 2.81 8.50
FC/MC/PC/UC60
42.0 3.52 3.45 25.0 2.60 2.81 8.50
HC60
42.0 3.52 3.45 25.0 2.60 2.81 8.50
HD60
42.0 3.52 3.45 25.0 2.60 2.81 8.50
THGD48S21S1
FC/MC/PC/UC60
48.0 3.40 4.13 37.0 2.76 3.97 7.70
FC/MC62
48.0 3.40 4.13 37.0 2.76 3.97 7.70
HC60
48.0 3.40 4.13 37.0 2.76 3.97 7.70
HD60
48.0 3.40 4.13 37.0 2.76 3.97 7.70
THGD60S21S1
FC/MC62
58.0 3.46 4.91 40.0 2.36 4.90 7.70
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.