18 02R Applications

Yamaha 02R & 03D Applications Guide

4

02R with ADAT & BRC

This application shows how the 02R can be used with an Alesis ADAT and BRC Master
Remote Control to create a 24-input, 8-track digital recording system. The eight digital tape
returns and 24 Mic/Line inputs provide up to 32 inputs at mixdown. In addition, the 02R’s
built-in automation and scene memory systems provide both dynamic and static mix
automation referenced to timecode.

Connections

The ADAT (CD8-AT) card must be screwed securely in place. Do not leave the screws out
after installation as the card will not be grounded correctly.

The Digital In/Out connectors on the 02R and ADAT are connected together using
Optical Cables. Press the DIGITAL IN button on the ADAT to use the DIGITAL IN.

The ADAT’s eight tracks connect to 02R slot [1], tape inputs one through eight.

The Alesis BRC Master Remote Control can control up to 16 ADATs (i.e. 128 tracks).

A 9-pin sync cable for connecting the ADAT and BRC is available from Alesis.

The BRC provides ADAT timecode to SMPTE timecode conversion. In addition, a
timecode offset can be specified, so the automix start time can be adjusted.

The 75 ohm wordclock termination switch on the back of the 02R is set to ON.

02R Wordclock Setup

On the DIGITAL I/O menu, the wordclock source should be set to W.CLK.

ADAT & BRC Wordclock Setup

The BRC works as wordclock master and the ADAT locks to it automatically via the 9-pin
sync cable. The sampling rate can be set to either 48 kHz or 44.1 kHz. Use Fixed mode for
48 kHz and Variable mode for 44.1 kHz (using the PITCH DOWN button, set to –147 cents.
At which point “–146, 44.1, –148” appears on the display). The newer ADAT-XT has
dedicated switches for selecting these two sampling rates.

Notes

Press the DIGITAL IN button on the ADAT to use the DIGITAL INPUT.

The ADAT must be powered up before the BRC, because when the BRC is powered up it
checks how many ADATs are connected, allocates them device numbers, and
automatically sets the system wordclock.

To generate timecode on the BRC, press the GEN SYNC button.

On the BRC, set the DIGITAL I/O button to OFF. This function is for direct ping-pong
between multiple ADATs. If this is turned ON while connected to an 02R, bus
assignments will produce unexpected results. Press the DIGITAL IN button on the
ADAT to use the DIGITAL INPUT.