User instructions, Running the appliance – Yeoman CL MILNER BRICK YMMB User Manual
Page 7
7
USER INSTRUCTIONS
5.5 When in use, burning the appliance at a high temperature
for a short period also reduces tars and creosotes.
WARNING: DO NOT OPERATE THE APPLIANCE WITH
THE PRIMARY AIR CONTROL OPEN FOR LONG
PERIODS OF TIME AS THIS COULD CAUSE OVER-
FIRING AND MAY CAUSE PERMANENT DAMAGE.
5.6 Burning Solid fuel:
—Set air controls (see diagram below).
Air Wash: 50% Open
Primary Air: 100% Open
Secondary Air:
Fully Closed
PR9031
PR9032
5.7 De-ash the firebed before re-fuelling (see User Instructions,
Section 7).
Open the Primary Air Control fully to establish a glowing
bed before adding new fuel.
Burn new fuel at a high temperature for a few minutes
before adjusting the Primary Air Control to the desired
setting.
Refuel little and often for clean, efficient burning.
5.8 Experience establishes settings to suit personal preference.
5.9 Do not burn large amounts of fuel with the Primary Air
Control
on a low combustion setting for long periods of
time. This reduces the glass cleaning effect of the Airwash
and causes tars and creosotes to build-up in the appliance
and flue system.
5.10 When in use, burning the appliance at a high temperature
for a short period reduces tars and creosotes.
5.11 Only anthracite or smokeless fuels suitable for use in
closed appliances must be burned in this appliance
.
5.12 Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this invalidates the product
guarantee
.
5.13 Do not load fuel above the log guard and the Secondary
Air Inlets at the back of the firebox
(see Diagram 8).
—
Do not refuel when a large amount of flame is
present in the firebox as this could cause smoke or
flames to spill into the room.
8
Air Inlets
Log Guard
PR9033
—Close the door.
Do not leave the door open as this could over-fire and
damage the appliance
.
5. RUNNING THE APPLIANCE
5.1 Burning Wood:
—Close the Primary Air control and use the Airwash to
control the temperature (see Diagram 9).
Air Wash:
Adjust
9
PR9030
—Wood burns best on a bed of ash (approx. 25mm (1")
deep).
—Rake the embers evenly over the firebed and open
the Airwash control fully for a few minutes before
re-fuelling.
—Do not close the Secondary Air control when
burning wood.
5.2 Burn new logs at a high temperature for a few minutes
before adjusting the Airwash control. Refuel little and often
for clean, efficient burning.
5.3 Experience establishes settings to suit personal preferences.
5.4 Do not burn large amounts of fuel with the Airwash control
closed for long periods of time. This reduces the glass
cleaning effect and causes tars and creosotes to build-up in
the appliance and flue system.