User instructions, Recommended fuels, Lighting the appliance – Yeoman CL MILNER BRICK YMMB User Manual
Page 6
6
USER INSTRUCTIONS
3. RECOMMENDED FUELS
3.1 Wood Logs:
Burn only seasoned timber with a moisture content of less
than 20%. To ensure this allow cut wood to dry for 12 to
18 months.
Wood Length
6
Appliance
Wood Length
CL Milner Brick
250mm
Poor quality timber:
— Causes low combustion efficiency.
— Produces harmful condensation.
— Reduces effectiveness of the airwash and life of the
appliance.
Do not burn construction timber, painted, impregnated
/ treated wood, manufactured board products or pallet
wood
.
3.2 Solid fuel:
Burn only anthracite or manufactured briquette smokeless
fuels listed as suitable for use with closed heating
appliances.
Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this will invalidate the product
guarantee
.
3.3 Fuel consumption.
As tested at nominal heat output to the requirements of EN
13229: 2001 for intermittent operation:
Description
Fuel Consumption
Kg/hour
Wood
Kg/hour
Briquette
Smokeless fuel
CL Milner Brick
1.6kg
1.2kg
3.4 For advice on suitable solid fuels contact your local
approved coal merchant*.
A number of factors can affect the performance of the
appliance, see User Instructions, Section 6 for details.
4. LIGHTING THE APPLIANCE
4.1 For best results:
Set air controls (see diagram below).
Air Wash: Fully Open
Primary Air: Fully Open
Secondary Air:
Fully Open
PR9028
PR9029
—Place firelighters or paper and dry kindling wood on the
grate.
—Light the paper or firelighters (see Diagram 7).
7
—Leave the door slightly open as the fire establishes and
the glass warms to avoid the build-up of condensation.
—Add larger pieces of wood. Too many logs may smother
the fire.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox
(s
ee Diagram 8).
—
Do not refuel when a large amount of flame is
present in the firebox as this could cause smoke or
flames to spill into the room.
*In the U.K.
• Ring the Solid Fuel Association advice line on
0845 601 4406 for details
• Visit their web site at www.solidfuel.co.uk