beautypg.com

Installation instructions, Removal of cleanburn chamber, Removal of cast iron firebricks – Yeoman CL MILNER BRICK YMMB User Manual

Page 22: Co alarms

background image

22

INSTALLATION INSTRUCTIONS

6. REMOVAL OF CLEANBURN CHAMBER

10

PR9045

Cap head screws

6.1 Remove the 4 M6 x 25 cap head screws using 5mm

hexagonal key.

6.2 Lift chamber, rotate forward and remove from stove.

6.3 Check rope seal is in good condition (see Diagram 11). If

necessary, replace using Yeoman 10 x 2 insulation tape

(Yeoman Part No. 4953).

11

PR9046

7. REMOVAL OF CAST IRON FIREBRICKS

7.1 Allow the appliance to cool fully before removing firebricks.

7.2 Replace damaged firebricks as soon as possible.

7.3 To remove bricks:

Remove grate (see Section 5).

Remove clean burn chamber (see Section 6).

Remove brick by rotating as shown in Diagram 12.

PR9047

12

8. CO ALARMS

All open flued appliances can be affected by temporary

atmospheric conditions which may allow fumes to enter

the house. Building regulations require that whenever

a new or replacement fixed solid fuel or wood/biomass

appliance is installed in a dwelling a carbon monoxide

alarm must be fitted in the same room as the appliance.

Further guidance on the installation of the carbon

monoxide alarm is available in the latest edition of

BS EN 50292 and from the alarm manufacturer's

instructions.

Provision of an alarm must not be considered a

substitute for either installing the appliance correctly

or ensuring regular servicing and maintenance of the

appliance and chimney system.