York E4TS030 THRU 060 User Manual
Page 8
036-21342-002 Rev. E (0505)
8
Unitary Products Group
HEATING CAPACITY - Variable Speed Air Handler
UNIT
MODEL
N1VS AIR HANDLER
COIL MODEL
1
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
HEATING
MODEL
ELECTRIC
HEAT KW
2
2. Single phase units require single phase 2HK heaters.
W
STAGE
(# CYL)
RATED
CFM
NET MBH
HSPF COP@ 47
47 OD
17 OD
E4TS030
N1VSB12
5,7.5,10,15,18
17
G2FD046S17
1
630
13400
–
–
3.80
2
630
24600
14400
8.7
3.48
2
1050
26400
15400
9.0
3.60
N1VSC16
5,7.5,10,15,20
21
G2FD042S21
1
650
13200
–
–
3.80
2
650
24200
14200
8.7
3.46
2
1065
26000
15200
9.0
3.58
G2FD048S21
1
650
13800
–
–
3.88
2
650
24800
14800
8.9
3.52
2
1065
27000
16000
9.2
3.64
E4TS036
N1VSC16
5,7.5,10,15,20
21
G2FD048S21
1
770
19600
–
–
3.78
2
770
31600
19000
8.7
3.52
2
1185
35000
20800
9.2
3.54
N1VSD20
7.5,10,15,20,25,30
24
G2FD048S24
1
780
20000
–
–
3.86
2
780
32000
19200
8.8
3.62
2
1200
35600
21200
9.3
3.74
E4TS048
F(2,3)FV060
10,15,20,25
24
–
1
1040
23800
–
–
3.66
2
1040
43500
24800
8.2
3.50
2
1600
47000
26400
8.5
3.58
N1VSD20
7.5,10,15,20,25,30
G2FD060S24
1
1040
23800
–
–
3.66
2
1040
43500
24800
8.2
3.50
2
1605
47000
26400
8.5
3.58
G2FD061H24
1
1040
24200
–
3.72
2
1040
44500
25600
8.4
3.58
2
1605
48000
27000
8.7
3.66
E4TS060
F(2,3)FV060
10,15,20,25
24
–
1
1220
25800
–
–
3.58
2
1220
51000
26400
8.1
3.32
2
1875
54000
28600
8.5
3.44
N1VSD20
7.5,10,15,20,25,30
G2FD060S24
1
1200
25800
–
–
3.58
2
1200
51000
26400
8.1
3.32
2
1860
54000
28600
8.5
3.44
G2FD061H24
1
1200
26600
–
–
3.64
2
1200
50500
26800
8.3
3.38
2
1860
55000
29200
8.7
3.50