beautypg.com

York E4TS030 THRU 060 User Manual

Page 18

background image

036-21342-002 Rev. E (0505)

18

Unitary Products Group

For notes see Page 11.

Multipliers for determining the performance with other indoor sections.

2-CYLINDER OPERATION

1-CYLINDER OPERATION

NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.

HEATING PERFORMANCE DATA

E4TS030S06A WITH N1VSC1606 / G2FD048S21 - HIGH CFM 2-CYLINDER OPERATION

ID CFM

980

1065

1210

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

35.86

2.17

36.10

2.19

36.34

2.20

70

33.48

2.30

33.93

2.31

34.39

2.32

80

31.09

2.43

31.77

2.44

32.44

2.45

47

60

28.88

2.04

29.01

2.07

29.14

2.09

70

26.78

2.14

27.00

2.17

27.22

2.19

80

24.68

2.24

24.99

2.26

25.29

2.29

35

60

22.40

1.90

22.79

1.92

23.17

1.94

70

20.57

1.98

20.94

2.00

21.31

2.02

80

18.73

2.05

19.10

2.08

19.46

2.10

17

60

16.95

1.71

17.09

1.74

17.22

1.78

70

15.20

1.77

15.40

1.84

15.60

1.83

80

13.46

1.83

13.71

1.94

13.97

1.88

7

60

12.23

1.50

12.34

1.52

12.45

1.54

70

11.24

1.57

11.39

1.60

11.53

1.61

80

10.24

1.64

10.43

1.68

10.62

1.68

-3

60

7.92

1.37

7.99

1.39

8.06

1.41

70

7.28

1.43

7.37

1.46

7.47

1.47

80

6.63

1.49

6.75

1.53

6.87

1.53

E4TS030S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION

ID CFM

650

720

770

OD DB

ID DB (°F)

MBTUH

1,2

KW

MBTUH

1,2

KW

MBTUH

1,2

KW

60

60

20.36

1.08

20.52

1.09

20.67

1.09

70

18.50

1.16

18.66

1.17

18.81

1.17

80

16.64

1.24

16.79

1.25

16.95

1.25

47

60

16.02

1.05

16.15

1.06

16.28

1.08

70

14.90

1.12

15.00

1.13

15.10

1.14

80

13.77

1.19

13.85

1.20

13.93

1.20

35

60

12.60

1.02

12.71

1.04

12.82

1.07

70

12.00

1.08

12.07

1.10

12.13

1.12

80

11.40

1.13

11.42

1.15

11.45

1.16

Air Handler

Coil

HIGH CFM

LOW CFM

MBTUH KW MBTUH KW

N1VSB12

G2FD046S17

0.98

0.99

0.91

0.96

N1VSC16

G2FD042S21

0.96

0.98

0.90

0.95

Variable Speed
Furnace

Coil

MBTUH KW MBTUH KW

P1XDB12V

G2FD046S17

0.97

1.00

0.89

0.94

P1XUB12V

G2FD046S17

0.96

1.00

0.88

0.95

P1XUB12V

G1UA048S17

0.96

1.00

0.88

0.95

P1XUB12V

G1FA048S17

0.96

1.00

0.88

0.95

P1DUB16V

G2FD046S17

0.98

1.00

0.90

0.95

P1DUB16V

G1UA048S17

0.98

1.00

0.90

0.95

P1DUB16V

G1FA048S17

0.98

1.00

0.90

0.95

P1DUC16V

G2FD042S21

1.00

1.00

0.92

0.95

P1DUC16V

G1UA048S21

1.01

1.01

0.93

0.96

P1DUC16V

GFA048S21

1.01

1.01

0.93

0.96

P1DUC16V

G2FD048S21

1.02

1.02

0.94

0.97

Air Handler

Coil

LOW CFM

MBTUH KW

N1VSB12

G2FD046S17

0.89

0.91

N1VSC16

G2FD042S21

0.88

0.90

Variable Speed
Furnace

Coil

MBTUH KW

P1XDB12V

G2FD046S17

0.85

0.93

P1XUB12V

G2FD046S17

0.85

0.93

P1XUB12V

G1UA048S17

0.85

0.93

P1XUB12V

G1FA048S17

0.85

0.93

P1DUB16V

G2FD046S17

0.83

0.91

P1DUB16V

G1UA048S17

0.83

0.91

P1DUB16V

G1FA048S17

0.83

0.91

P1DUC16V

G2FD042S21

0.87

0.91

P1DUC16V

G1UA048S21

0.88

0.92

P1DUC16V

GFA048S21

0.88

0.92

P1DUC16V

G2FD048S21

0.89

0.92