York E4TS030 THRU 060 User Manual
Page 20
036-21342-002 Rev. E (0505)
20
Unitary Products Group
For notes see Page 11.
Multipliers for determining the performance with other indoor sections.
1-CYLINDER OPERATION
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HEATING PERFORMANCE DATA
E4TS036S06A WITH N1VSC1606 / G2FD048S21 - LOW CFM 1-CYLINDER OPERATION
ID CFM
670
770
860
OD DB
ID DB (°F)
MBTUH
1,2
KW
MBTUH
1,2
KW
MBTUH
1,2
KW
60
60
24.27
1.49
24.88
1.50
25.48
1.51
70
22.72
1.59
23.42
1.61
24.13
1.62
80
21.16
1.70
21.96
1.71
22.77
1.73
47
60
21.43
1.42
21.73
1.43
22.04
1.44
70
19.73
1.51
20.00
1.52
20.42
1.53
80
18.03
1.59
18.42
1.61
18.81
1.62
35
60
18.92
1.36
18.99
1.36
19.06
1.37
70
17.14
1.42
17.22
1.44
17.30
1.45
80
15.35
1.49
15.45
1.51
15.54
1.52
Air Handler
Coil
LOW CFM
MBTUH
KW
N1VSB12
G2FD046S17
0.98
1.00
Variable Speed
Furnace
Coil
MBTUH
KW
P1XDB12V
G2FD046S17
0.87
0.94
P1XUB12V
G2FD046S17
0.86
0.94
P1XUB12V
G1UA048S17
0.87
0.94
P1XUB12V
G1FA048S17
0.87
0.94
P1DUB16V
G2FD046S17
0.85
0.93
P1DUB16V
G1UA048S17
0.86
0.93
P1DUB16V
G1FA048S17
0.86
0.93
P1DUC16V
G1UA048S21
0.85
0.93
P1DUC16V
G1FA048S21
0.85
0.93
P1DUC16V
G2FD048S21
0.86
0.93
P1DUC16V
G1UA060S21
0.88
0.94
P1DUC16V
G1FA060S21
0.88
0.94
Variable Speed
Furnace
Coil
LOW CFM
MBTUH
KW
P1DUC20V
G1UA048S21
0.85
0.93
P1DUC20V
G1FA048S21
0.85
0.93
P1DUC20V
G2FD048S21
0.86
0.93
P1DUC20V
G1UA060S21
0.88
0.94
P1DUC20V
G1FA060S21
0.88
0.94
P1XUC20V
G1UA048S21
0.83
0.92
P1XUC20V
G1FA048S21
0.83
0.92
P1XUC20V
G2FD048S21
0.84
0.92
P1XUC20V
G1UA060S21
0.86
0.93
P1XUC20V
G1FA060S21
0.86
0.93
P1XDD20V
G2FD048S24
0.90
0.98
P1XUD20V
G1UA048S24
0.90
0.99
P1XUD20V
G1FA048S24
0.90
0.99
P1XUD20V
G2FD048S24
0.91
0.99
P1XUD20V
G1UA060S24
0.94
1.00
P1XUD20V
G1FA060S24
0.94
1.00