York YMA024 User Manual
Page 20
036-21570-002 Rev. D (0605)
20
Unitary Products Group
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YMA04211
INDOOR COIL MODEL NO.
G2FD048S21
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1200
1400
1600
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
MBTUH
KW
C.O.P.
60
60
49.8 3.6 4.1 50.8 3.4 4.4 51.9 3.3 4.6
70
47.2 3.9 3.6 48.2 3.7 3.8 49.2 3.6 4.0
80
44.7 4.2 3.1 45.7 4.1 3.3 46.6 3.9 3.5
47
60
43.7 3.3 3.9 44.5 3.2 4.1 45.3 3.1 4.3
70
41.3 3.6 3.3 42.0 3.5 3.5 42.7 3.4 3.7
80
38.9 4.0 2.9 39.5 3.8 3.0 40.1 3.7 3.2
40
60
40.0 3.2 3.7 40.8 3.1 3.8 41.5 3.0 4.0
70
37.9 3.5 3.1 38.5 3.4 3.3 39.1 3.3 3.4
80
35.8 3.8 2.7 36.2 3.7 2.8 36.6 3.6 3.0
30
60
36.0 3.1 3.4 36.5 3.0 3.6 37.1 2.9 3.7
70
33.9 3.4 2.9 34.3 3.3 3.1 34.7 3.2 3.2
80
31.8 3.7 2.5 32.1 3.6 2.6 32.4 3.5 2.7
17
60
28.5 3.2 2.6 28.9 3.1 2.7 29.3 3.1 2.8
70
27.6 3.4 2.4 28.0 3.3 2.5 28.4 3.2 2.6
80
26.8 3.5 2.2 27.1 3.4 2.3 27.4 3.4 2.4
10
60
27.9 2.8 2.9 28.5 2.8 3.0 29.1 2.7 3.1
70
26.0 3.1 2.4 26.4 3.1 2.5 26.8 3.0 2.6
80
24.1 3.4 2.1 24.3 3.4 2.1 24.5 3.3 2.2
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler
Coil
MBH
KW
COP
F2FP048
0.99 0.99 1.00
N1VSC16
G2FD048(S,H)21(T)
0.98 1.04 0.94
N1VSD20
G2FD048(S,H)24(T)
0.98 1.05 0.93
N1AHC16
G2FD048(S,H)21(T)
1.00 1.00 1.00
N1AHD20
G2FD048(S,H)24(T)
1.00 1.00 1.00
G1FA048S21
1.00 1.00 1.00
G2FD048(S,H)21,24
1.00 1.00 1.00
G1NA060S24T
1.01 1.02 0.99
G1HD048
0.99 0.99 0.99
G1HA048H21
0.99 1.00 0.99
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
P*DUC20V
G1FA048S21
0.99 1.03 0.96
P*DUC20V
G2FD048(S,H)21(T) 1.00 1.05 0.95
P1XUC16V
G1FA048S21
0.99 1.03 0.96
P1XUC16V
G2FD048(S,H)21(T) 1.00 1.05 0.96
P1XUC20V
G1FA048S21
0.99 1.02 0.97
P1XUC20V
G2FD048(S,H)21(T) 1.00 1.04 0.96
P1XDD20V
G2FD048(S,H)24(T) 1.00 1.02 0.98
P1XDC20V
G2FD048(S,H)21(T) 1.00 1.01 0.99
P1XDC20V
G1HA048H21
0.99 1.00 0.99
P1XDD20V
G2FD048(S,H)24(T) 1.00 1.02 0.98