Troubleshooting

When problems occur, then troubleshoot as needed by using the following information
as a guide. Be sure to always also refer to sections on “Troubleshooting” in the controller
user’s manual as well as the instruction manual for the other party’s equipment such as
PCs or HUB peripheral devices. If taking the troubleshooting steps listed there does not
eliminate the problem, then quickly contact your local YAMAHA sales dealer.

Checkpoints

• Disconnect the controller from the

network and connect the PC instead.
(Use a PC capable of a good
connection with the network. Make the
same IP address, subnet mask and
gateway settings as used on the
controller.)
Now try running “ping” from the client
while setup as above, and check for a
response.

• Check if securely attached to the

modular connector.

• Check for a disconnection (or break) in

the cable or a miswire.

• Check if the straight-through cable or

crossover cable are being used for the
wrong connection.

• Try replacing the cables.

• Try changing to another port.
• Check if the communication mode is

manually set to other than 10Mbps/Half
Duplex.

• Try another HUB

• Check the router settings.
• Try substituting with another router.

• Check the network settings on the

client side.

• Try substituting with another network

adapter on the client side.

• Check if the traffic load is appropriate.

• Check how and where the Ethernet

cables are installed.

Action

• If timeouts still occur when connected

this way (using PC instead of
controller), then the problem is on the
client side or in the HUB peripheral
device. (Check probable causes 1
through 6.)

• If a replay comes back normally, then

the problem is in the controller, so
check probable causes 7 through 8.

• Insert in firmly until a click noise is

heard.

• Correct the wiring if a miswire is

found. Replace the cable if a break in
the wiring is found.

• Use a straight-through cable between

the HUB and controller. Use a
crossover cable if connecting directly
to the other party’s device.

• If operation returns to normal, then the

problem is in the cables. Replace the
cable.

• If operation returns to normal then the

port is defective, so do not use that
port.

• When setting the HUB communication

mode manually, then set it to
10Mbps/Half Duplex.

• If operation returns to normal then the

HUB is defective, so replace the HUB.

• Redo the router settings.
• If operation returns to normal then the

router is defective so replace the
router.

• Redo the network settings on the client

side.

• If operation returns to normal then the

network adapter is defective so replace
the adapter.

• Change the network structure to get a

smaller traffic load.

• Separate the Ethernet cable from

potential noise sources.

No.

1

Probable causes

Ethernet cable
defects, poor
connection, or
wrong specs.

Defective HUB
or wrong settings

Router is
defective or
wrong settings

Network adapter
used by the client
is defective or the
settings on the
client side are
wrong.
Network traffic
(communication
data load) is too
heavy.
Ethernet cable is
too close to a
noise source such
as motor cables.

1)

2)

3)

4)

5)

6)