4-1 validating the ethernet unit – Yamaha DRCX User Manual
Page 17
11
CHAPTER2 Ethernet Unit
2-4
Making system settings for the controller (server)
A minimum of IP address, subnet mask and gateway settings must be made so that the
controller will be correctly identified and acknowledged on Ethernet.
These settings are made from the TPB and enabled after the controller is restarted.
2-4-1
Validating the Ethernet unit
Before the Ethernet unit can be used, it must first be set as follows, to allow it to be
identified by the controller.
1)
Press
F3
(SYS) on the initial menu
screen.
2)
Press
F4
(next) to switch the function
display and then press
F2
(OPT).
3)
Press
F1
(DEV).
4)
The current Ethernet unit identity status
appears on the display.
Using the number keypad, enter “1” to
make the Ethernet unit identifiable from
the controller or enter “0” to prevent it
being identified from the controller, and
then press the
key.
5)
The screen returns to the previous display
in step 4.
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE2OPT 3UTL 4next
[SYS-OPT]
select menu
1DEV 2MAC 3VER 4next
[SYS-OPT-DEV]
Ethernet= 0
0:invalid 1:valid
[SYS-OPT-DEV]
Ethernet= 1
0:invalid 1:valid