7
A
Specifications
Specifications are subject to change without notice.
Mechanical Specifications
Electrical Performance
Physical Specifications
XADC-40
XADC-60
XADC-80
Weight
7.9 lb
(3.6 kg)
8.2 lb
(3.7 kg)
8.3 lb
(3.8 kg)
Operating temperature range
14 ºF – 86 ºF (-10 ºC – 30 ºC)
de-rated 86 ºF – 140ºF (30 ºC – 60 ºC)
> 140ºF (60 ºC) unit may shut down
Length
11 13/16 in. (300.0 mm)
Width
7 1/8 in. (180.0 mm)
Height
4 3/4 in. (120.0 mm)
AC Input
XADC-40
XADC-60
XADC-80
Input current (at rated output)
6 Aac
9 Aac
12 Aac
Nominal input voltage
120 Vac, 60 Hz
Normal operating input voltage
108 Vac – 130 Vac
Min. operating input voltage
90 Vac
Max. operating input voltage
140 Vac
Power factor (rated output, nominal input)
≥ 0.95
Safe (non-operating) input voltage range
0 – 150 Vrms
Frequency
50 – 70 Hz