beautypg.com

Appendix a: service information, Warranty service, Troubleshooting – MACKIE ONYX 1200F User Manual

Page 30: Onyx 1200f

background image

0

ONYX 100F

ONYX 1200F

Appendix A: Service Information

Bad Output

• If the DSP Mixer is turned on in the Console, make

sure the output level control for the suspect output
is turned up and the meters are indicating that a
signal is present.

• If another output is working correctly, try switching

the output connections between the working output
and the suspect output. If the working output stops
working, it could be a bad cable or the device to
which it is connected.

• If it’s the S/PDIF OUT [28], make sure the S/PDIF

Format is set to Consumer in the Console Settings
window. If it is set to Consumer and is not working,
try using the Professional setting.

Bad Sound

• Is the input connector plugged completely into the

jack?

• Is it loud and distorted? Make sure the input GAIN

control for the channel is set correctly. Reduce the
signal level on the input source if possible.

• Are the Onyx 1200F and the device to which it is

connected locked to the same clock? If the Onyx
1200F is operating on its own internal sample rate,
make sure the device to which it is connected is set
to external clock and is locking to the clock signal
either through the WORD CLOCK OUT, ADAT OUT,
or the S/PDIF connections. If the Onyx 1200F is set
to external Word Clock, make sure it is locked to
the external clock.

• If possible, listen to the signal with headphones

plugged into the input source device. If it sounds
bad there, it’s not the Onyx causing the problem.

Noise/Hum

• Turn down each channel, one by one. If the noise

disappears, it’s coming from whatever is plugged
into that channel.

• Check the signal cables between the input sources

and the Onyx. Disconnect them one by one. When
the noise goes away, you’ll know which input source
is causing the problem.

• Sometimes it helps to plug all the audio equipment

into the same AC circuit so they share a common
ground.

No Audio into your Computer

• Confirm that the Onyx 1200F is receiving mic or

line-level input signals (the meters should indicate
signal is present in the Onyx 1200F Console).

Warranty Service

Details concerning Warranty Service are spelled out in
the Warranty section on page 35.

If you think your Onyx 1200F has a problem, please
check out the following troubleshooting tips and do your
best to confirm the problem. Visit the Support section of
our website (www.mackie.com/support) where you will
find lots of useful information such as FAQs, documenta-
tion, and user forums. You may find the answer to the
problem without having to send your preamp away.

Troubleshooting

No Power

• Our favorite question: Is it plugged in?

• Make sure the power cord is securely seated in the

IEC socket [34] and plugged all the way into the
AC outlet.

• Make sure the AC outlet is live (check with a tester

or lamp).

• Is the POWER [20] switch on? Make sure the

POWER switch on the front panel is in the ON posi-
tion (up).

• Are any LEDs on the front panel illuminated? One

of the clock, metering, and sample rate LEDs
should be lit. If not, make sure the AC outlet is live.

• Are all the lights out in your building? If so, contact

your local power company to get power restored.

• If there are no LEDs illuminated on the front panel,

and you are certain that the AC outlet is live, it will
be necessary to have your Onyx 1200F serviced. There
are no user serviceable parts inside.
Refer to “Repair”
at the end of this section to find out how to proceed.

Bad Channel

• Is the input GAIN control [4] for the channel

turned up (channels 1-12)?

• Is the signal source turned up? Make sure the signal

level from the selected input source is high enough
to light up some of the INPUT meter [1] LEDs for
that channel (channels 1-12).

• If it is channel 11 or 12, make sure the Instrument

switch [6] is in the right position.

• Try the same source signal in another channel, set