Parameter Edit Mode - 15

D5000

of a

DUCK

) for a very short time. This can sound unnatural, especially if the

GATE

closes abruptly.

There are two parameters which you can adjust,

HOLD

and

RELEASE

. By setting a long

HOLD

time,

the gate can be kept open even after the signal has dropped below the threshold. The

RELEASE

parameter specifies the length of time it takes for the gate to close, causing the signal to gradually
cut off.

Other triggers

The signal level is not the only way to trigger a duck/gate. The

[TRIGGER] key or a footswitch

connected to the TRIGGER Footswitch Jack on the back panel, or a MIDI Note On (for

GATE

) or

Note Off (for

DUCK

) message can also be used. The

HOLD

and

RELEASE

parameters work with any

trigger.

Re-trigger

If the

DUCK

/

GATE

is continuously triggered by any of the other sources, it may be kept from

closing. As the

GATE

responds to a trigger source and will open for the set

HOLD

time, a trigger

received while the

GATE

is open will act as a "re-trigger", causing the

GATE

to remain open.

Threshold

Hold

Release

Input Signal

Delay Output (TYPE set to GATE)