Symptom

Fault indicator light flashes. XC Series stops functioning.

Symptom

Fault indicator light illuminates. 100% indicator light flashes.

Symptom

Fault indicator light illuminates. 10% indicator light flashes.

Symptom

XC Series completes a charging cycle, but the battery voltage seems (about 2 volts)
too low.

Possible Cause

Solution

XC Series hardware failure

Call for service

Possible Cause

Solution

Battery temperature is too hot for
safe charging.

Allow battery to cool. Improve ventilation or
install in cooler location. It may indicate a shorted
cell in the battery or excessive water loss.

Possible Cause

Solution

Battery temperature is too cold for
safe charging.

Allow batteries to warm up before attempting to
charge again. Charging a battery that has frozen is
a potential explosion hazard.

Possible Cause

Solution

Battery has a shorted cell.

Check the battery.
Verify you are attempting to charge a battery correctly
rated at 12 volts nominal (XC3012, XC5012) or 24
volts nominal (XC1524, XC2524). Re-check the
battery voltage with all loads removed and the battery
is at rest for about an hour.