beautypg.com

Xantrex Technology XC1524 User Manual

Page 63

background image

Error Messages on Remote Display

975-0187-01-01

4–5

Err

CLd

Red fault indicator light
illuminated
Green 10% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated

Battery Too
Cold
Shutdown

Allow batteries to warm up before
attempting to charge again. Charging a
battery that has frozen is a potential
explosion hazard.

DIS

25% current indicator light
flashes

Battery
Disqualified
Warning

Wait 15 minutes for the next battery
detection cycle. The warning may be
temporary.
Verify that the battery meets the minimum
AmpHour rating (XC1524: 30 Ah,
XC2524: 50 Ah, XC3012: 60 Ah,
XC5012: 100 Ah)
Try adding a small DC load.
Replace the battery.

HI

Display green bank indicator
light for the affected battery
bank illuminated

Over Voltage
Shutdown
Warning

Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with electric start.
If the warning level escalates without
being corrected, the XC Series enter the
fault level and stop charging the affected
bank.

Err

HI

Red fault indicator light
illuminated
Display green bank indicator
light for the affected battery
bank illuminated

Over Voltage
Shutdown

Check battery. Do not charge a battery
rated at more than 12 volts nominal
(XC3012, XC5012) or 24 volts nominal
(XC1524, XC2524).
Disconnect or turn off other charging
sources such as the alternator or the
charger on a generator with electric start.

Table 4-2 Error Messages

Display

Onboard Status Panel
Indicator lights

Fault

Solution

XC_Charger_Owner.book Page 5 Friday, August 12, 2005 3:23 PM