Xantrex Technology XC1524 User Manual
Page 54
Operation
3–12
975-0187-01-01
Table 3-1 Reading XC Series Status
Charger Status
Remote
Display
Onboard Status Indicator Lights
Charging in bulk or absorption mode.
Remote display shows scrolling display of charging
state, battery voltage in volts and charging current in
amps.
Indicator lights indicate the charging current in % of
full charge. At transition points when the current is
changing, two indicator lights may flash alternately,
then settle into the new charging current reading.
BUL or
ABS
Charging indicator light illuminates
Equalizing.
Charging indicator light flashes once every four
seconds if bank 1 is being equalized, twice every four
seconds if bank 2 is being equalized, and three times
every four seconds if bank 3 is being equalized.
EQU
Charging indicator light flashes
Float mode of three stage charging or rest mode of
two stage charging.
All batteries have been fully charged.
FLo or
Rdy
Ready indicator light illuminates
A battery has been disqualified while in float mode of
three stage charging or rest mode of two stage
charging.
FLo or
rdy
25% current indicator light flashes
A battery has been disqualified while in bulk or
absorption mode.
dis
25% current indicator light flashes
Non-charger fault condition.
Any fault condition that prevents the charger from
charging one or more banks, but is not a charger
failure. Remote display shows details of fault.
ERR
BAT
PoL
(example)
Fault indicator light illuminates