beautypg.com

Error messages on remote display – Xantrex Technology XC1524 User Manual

Page 62

background image

Troubleshooting

4–4

975-0187-01-01

Error Messages on Remote Display

Table 4-2 Error Messages

Display

Onboard Status Panel
Indicator lights

Fault

Solution

ERR

Red fault indicator light
flashing or illuminated

Fault

A fault has been detected. The fault code
will be shown immediately after

Err.

ACL

AC Low
Warning

Check AC connections, check AC
availability at source.

Err

bat

PoL

Red fault indicator light
illuminated

Reverse
Polarity

Reverse Polarity Battery connected.
Check connections. Ensure correct
polarity (negative connected to negative,
positive connected to positive).

Err

CHf

Red fault indicator light
flashing

Charger
Hardware
Fault

Call for service.

CHg

Hot

Over-
temperature
Warning

Allow the XC Series to cool. Improve
ventilation or install in cooler location. If
the temperature increases, the XC Series
will enter the fault level and stop
functioning.

Err

CHg

Hot

Red fault indicator light
illuminated

Over-
temperature
Shutdown

Allow the XC Series to cool. Improve
ventilation or install in cooler location.

CLd

Green 10% indicator light
flashes
Display green bank indicator
light for affected battery bank
illuminated

Battery Too
Cold Warning

Allow batteries to warm up before
attempting to charge again. Charging a
battery that has frozen is a potential
explosion hazard. If the temperature
drops, the XC Series will enter the fault
level and stop charging the affected bank.

XC_Charger_Owner.book Page 4 Friday, August 12, 2005 3:23 PM