York YCJD18 THRU 60 User Manual
Page 5
561908-YTG-A-0410
Johnson Controls Unitary Products
5
— = Not applicable.
13 SEER AC WITH AHP / SHP / AHX / F*FP
YCJD18S41S3(H)
AHP18 17
–
650
17.5
12.9
13.00
11.00
AHX18
17
-
630
18.0
13.8
14.50
12.00
F4FP024 18
–
600 17.5 12.9
13.00
11.00
F6FP018
17
-
600
17.8
13.3
14.50
12.00
YCJD24S41S3(H)
AHP30 17
–
795
24.0
16.8
13.00
11.00
AHX30
17
–
820
24.0
16.9
14.50
12.00
AHX36
21
–
815
24.0
16.9
14.50
12.00
F4FP036
21.5
–
800
24.0
16.7
13.00
11.00
F6FP030
17
–
850
24.0
16.8
14.00
11.80
F6FP036
21
–
855
24.0
17.0
14.00
12.00
YCJD30S41S3(H)
AHP30 17
–
1015
29.0
21.0
13.00
11.00
AHP36 21
–
1040
29.0
21.0
13.00
11.00
AHX30
17
–
1025
29.4
22.2
14.00
11.75
AHX36
21
–
1005
30.0
22.3
14.50
12.00
F4FP040 18
–
1050 29.0 21.0
13.00
11.00
F6FP030
17
–
1035
29.2
21.6
13.50
11.40
F6FP036
21
–
980
29.4
21.4
14.00
12.00
YCJD36S41S3(H)
AHP36 21
–
1235
35.0
24.8
13.00
11.00
AHP42 21
–
1255
35.0
24.8
13.00
11.00
AHX36
21
–
1225
35.2
25.0
13.50
11.50
AHX42
21
–
1190
35.4
25.2
14.00
11.80
F5FP048 24
–
1235 35.0 24.8
13.00
11.00
F6FP042
21
–
1290
35.8
25.8
13.50
11.50
YCJD42S41S3(H)
AHP42 21
–
1485
41.0
29.2
13.00
11.00
AHX42
21
–
1395
42.0
29.9
14.50
12.00
F5FP048 24
–
1455 41.0 29.2
13.00
11.00
F6FP042
21
–
1455
42.0
30.1
14.00
11.75
F6FP048
24
–
1380
41.5
29.4
13.50
11.70
YCJD48S41S3(H)
AHP/SHP48 24
–
1675 48.0 34.4 13.00 11.00
AHP/SHP60 24
–
1600 48.0 35.0 13.50 11.00
AHX48
24
–
1660
48.0
35.4
13.50
11.50
F5FP048 24
–
1600 48.0 34.4
13.00
11.00
F5FP060 24
–
1600 48.0 34.4
13.00
11.00
F6FP048
24
–
1625
47.0
34.8
13.00
11.30
YCJD60S41S3
AHP/SHP60 24
–
1850 57.0 38.5 13.00 11.00
AHX60
24
–
1905
58.5
40.0
13.50
11.50
F5FP060 24
–
1900 57.0 38.5
13.00
11.00
F6FP060
24
–
1710
57.5
39.0
13.50
11.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL
W
RATED
CFM
NET MBH
SEER
EER
TOTAL
SENS.