beautypg.com

Operating instructions, Cgi, cgs, Spark-ignited pilot – Weil-McLain CGi User Manual

Page 21: User’s information manual

background image

User’s Information Manual

21

Part Number 550-110-592/1000

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

TO TURN OFF GAS TO THE APPLIANCE

Do not try to light any appliance.

Do not touch any electric switch; do not use
any phone in your building.

Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

WHAT TO DO IF YOU SMELL GAS

A. This appliance does not have a pilot. It is equipped

with an ignition device which automatically lights
the burner.

Do not

try to light the burner by hand.

B. Before

OPERATING

, smell all around the

appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle on the floor. See below.

C. Use only your hand to turn the gas control knob. Never use

tools. If the knob will not turn by hand, don't try to repair it,
call a qualified service technician. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control, which has been under water.

If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.

1.

STOP

! Read the safety information above on this label.

2. Set the thermostat to lowest setting.

3. Turn off all electrical power to the appliance.

4. Remove jacket front panel.

5. This appliance is equipped with an ignition device which automatically lights the burner.

Do not try to light the burner by hand.

6. Turn

Gas control knob

clockwise

to

OFF

.

7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If

you smell gas,

STOP

! Follow "B" in the safety information above. If you don't smell gas,

go to the next step.

8. Turn

Gas control knob

counterclockwise

to

ON

.

9. Turn on all electric power to the appliance.

10. Set thermostat to desired setting.

11. If the appliance will not operate, follow the instructions "

TO TURN OFF GAS TO

APPLIANCE

" below and call your service technician or gas supplier.

12. Replace jacket front panel.

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance if service is to

be performed.

26070

Position indicator

(shown in "ON" position)

White-Rodgers

36C Gas valve

White-Rodgers

36E Gas valve

Honeywell

VR8204 or

VR8304

Gas valve

Position indicator

(shown in "ON" position)

Gas control knob

Gas control knob

Gas control knob

Position indicator

(shown in "ON" position)

Operating instructions

Spark-ignited pilot

CGi, CGs

Gas valve — Honeywell VR8204/VR8304, White-Rodgers 36C and 36E

3. Remove jacket front panel.

4. Turn

Gas control knob

clockwise

to

OFF

. Do not

force.

5. Replace jacket front panel.

This manual is related to the following products: