Page 14

background image

CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers

14

Part Number 550-110-592/1000

Gas valve — Robertshaw 7200

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

TO TURN OFF GAS TO THE APPLIANCE

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone
in your building.

Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire
department.

WHAT TO DO IF YOU SMELL GAS

A. This appliance has a pilot, which must be lighted

by hand. When lighting the pilot, follow these
instructions exactly.

B. Before

LIGHTING

, smell all around the appliance

area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor. See below.

C. Use only your hand to depress the selector arm. Never use tools. If

the selector arm will not move by hand, don't try to repair it, call a
qualified service technician. Force or attempted repair may result in
a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.

If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.

1.

Stop!

Read the safety information above on this label.

2. Set the thermostat to lowest setting.
3. When equipped with

Effikal

vent damper

Model RVGP,

place service switch in

Hold Damper Open

position.

4. Turn off all electrical power to the appliance.
5. When equipped with

Johnson Controls

vent damper

Model M35,

manually rotate damper blade in direction

of arrow to

Open

position indicated on damper assembly.

6. Depress and move selector arm left

to

OFF

.

7. When equipped with vent damper, verify damper blade

is in full open position.

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance if service is to

be performed.

3. Remove front panel.

4. Depress and move selector arm left

to

OFF

.

5. Replace front panel.

8. Wait five (5) minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas,

STOP!

Follow

"B"

in the safety information above. If you don't smell

gas, go to the next step.

9. Remove access panel located above burners.
10. Find pilot — follow metal tube from gas

control. The pilot is between two burners
behind the access panel.

11. Move selector arm on gas control right

to

SET

position.

Lighting instructions

Standing pilot

Position
indicator

Selector
arm

(shown in

position)

OFF

59332

CGa-25 to CGa-6,
EG-30 to EG-50,
PEG-30 to PEG-50

12. Hold selector arm in

SET

position and immediately light

the pilot with a match. Continue to hold selector arm to

SET

for about one-half (

1

/

2

) minute after the pilot is lit.

13. Release selector arm. If pilot does not remain lit, repeat

steps 6 through 13.

If the pilot will not stay lit after several tries, move
selector arm left

to

OFF

and call your service

technician or gas supplier.

14. Replace access panel.
15. Turn selector arm left

to

ON

.

16. Turn on all electric power to the appliance.
17. When equipped with

Effikal

vent damper, place service

switch in

Automatic Operation

position.

18. Set thermostat to desired setting.
19. Replace front panel.