Lighting instructions, Standing pilot • gas valve — robertshaw 7000erhc – Weil-McLain CGi User Manual
Page 15

Users Information Manual
15
Part Number 550-110-592/1000
FOR YOUR SAFETY READ BEFORE LIGHTING
OPERATING INSTRUCTIONS
TO TURN OFF GAS TO THE APPLIANCE
•
Do not try to light any appliance.
•
Do not touch any electric switch; do not use any phone
in your building.
•
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire
department.
WHAT TO DO IF YOU SMELL GAS
If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life.
1.
Stop!
Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electrical power to the appliance.
4. Depress gas control knob slightly and turn clockwise
to
OFF
.
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to
be performed.
3. Remove front panel.
4. Depress gas control knob slightly and turn clockwise
to
OFF
.
5. Replace front panel.
5. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas,
STOP!
Follow
"B"
in the safety information above. If you don't smell
gas, go to the next step.
6. Remove access panel located above burners.
7. Find pilot — follow metal tube from gas
control. The pilot is between two burners
behind the access panel.
Lighting instructions
•
Standing pilot
•
Gas valve — Robertshaw 7000ERHC
A. This appliance has a pilot, which must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B. Before
LIGHTING
, smell all around the appliance
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor. See below.
C. Use only your hand to depress or turn the gas control knob. Never
use tools. If the selector arm will not depress or move by hand, don't
try to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.
Gas control knob
Position
indicator
(shown in
position)
ON
59205
EG-75, EGH-85, EGH-95,
PFG-6, PFG-7
Note:
Gas control knob cannot be turned to
OFF
unless knob is
depressed slightly. Do not force.
8. Turn gas control knob counterclockwise
to
PILOT
.
9. Depress gas control knob and hold. Immediately light the
pilot with a match. Continue to hold gas control knob in
for about one (1) minute after the pilot is lit.
•
If pilot can be lit without depressing gas control knob,
turn gas knob clockwise
to
OFF
and call your ser-
vice technician or gas supplier.
10. Release gas control knob. Pilot should remain lit. If pilot
goes out, repeat steps 4 through 10.
•
If gas control knob stays depressed after release, stop
and immediately call your service technician or gas
supplier.
•
If the pilot will not stay lit after several tries, turn the
gas control knob clockwise
to
OFF
and call your
service technician or gas supplier.
11. Replace access panel.
12. Turn gas control knob counterclockwise
to
ON
.
13. Turn on all electric power to the appliance.
14. Set thermostat to desired setting.
15. Replace front panel.