beautypg.com

Start — or — shutdown boiler, Lighting instructions, End-of-season shutdown – Weil-McLain CGi User Manual

Page 12: Follow boiler shutdown procedure, Propane gas odorant

background image

CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers

12

Part Number 550-110-592/1000

Follow boiler shutdown procedure

End-of-season shutdown . . . . . . . .

1. Follow “

TO TURN OFF GAS TO APPLIANCE

” on

the

Lighting/Operating instructions

on the inside

of the jacket panel. You will also find these
instructions on pages 13 through 22 of this manual.

Use the

Lighting/Operating instruction

for the gas

valve model installed on the boiler.

2. Do not drain system unless exposure to freezing

temperatures will occur.

3. Do not drain the system if it is filled with an

antifreeze solution.

4. Do not shut down boilers used for domestic water

heating. They must operate year-round.

Propane boilers only

— Your propane supplier mixes an odorant with the propane to make its presence detect-

able. In some instances, the odorant can fade and the gas may no longer have an odor.

Propane gas can accumulate at floor level. Smell near the floor for the gas odorant or any unusual odor. If you
suspect a leak, do not attempt to light the pilot.

Use caution when attempting to light the propane pilot. This should be done by a qualified service techni-
cian, particularly if pilot outages are common.

Periodically check the odorant level of your gas.

Inspect boiler and system at least yearly to make sure all gas piping is leak-tight.

Consult your propane supplier regarding installation of a gas leak detector. There are some products on the
market intended for this purpose. Your supplier may be able to suggest an appropriate device.

Propane gas odorant

Table 2

Lighting /

Operating

instruction

guide

Standing pilot

Models

Page Spark-ignited pilot

Models

Page

Honeywell VR8200/VR8300

CGa-25 – CGa-8
EG-30 – EG-65
PEG-30 – PEG-55

13

Honeywell VR8204/VR8304

CGa-25 – CGa-8
EG-30 – EG-75
PEG-30 – PEG-55
PFG-5

16

CGi, CGs

21

White-Rodgers 36E

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

17

Robertshaw 7200

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

14

CGi
CGs

21

Robertshaw 7000ERHC

EG-75
EGH-85, EGH-95
PFG-6, PFG-7

15

White-Rodgers 36C

CGa-7, CGa-8
EG-55 – EG-75
PEG-55, PFG-5

18

CGi, CGs

21

Robertshaw 7200

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

19

Robertshaw 7000 DERHC

EGH-85 – EGH-125
PFG-6 – PFG-8

20

--

LGB

22

Lighting instructions

Use

Table 2

below to locate the correct Lighting/Operating instruction for the gas valve model installed on your

boiler.

This manual is related to the following products: