38a.The following instructions are critical to the cor-

rect operation of your weight system. If the
adjustment is incorrect, it can damage the motor.
Make sure that you read and understand these
instructions before attempting to adjust the
Weight Mechanism (26).

See page 20 for instructions on how to operate the
console. Set the console to the maximum weight
reading (H250) as shown in the inset drawing. If the
motor binds or hesitates, stop running the console
and loosen the locknut shown in step 38c until the
console reaches the maximum weight reading.

Next, apply lubricant to the indicated screw.

38a

38b.Check the brass piece that is pictured at the right. It

should barely be touching the shaded area on the
Weight Mechanism (26) and should move slightly
from side to side.

If the brass piece is too loose, there will be a
noticeable time lapse between the time an exer-
cise is started and the time resistance is felt. If
the brass piece is too tight, the Weight
Mechanism (26) will have difficulty moving and
may become jammed so that no movement can
occur.

38b

Brass

Piece

26

38c.To adjust the Weight Mechanism (26), begin with the

ÒUÓ-bracket found on one end of the Mechanism. If
the brass piece is too loose, tighten the indicated 3/8Ó
Nylon Locknut (57) 1/4 turn. If the brass piece is too
tight, loosen the Locknut 1/4 turn.

Re-check the clearance between the brass piece and
the Weight Mechanism (26) after each adjustment
until the brass piece is barely touching the shaded
area on the Mechanism. It should move slightly from
side to side.

38c

57

26

57

ÒUÓ-bracket

37. Plug one end of the Power Adapter Cord (64) into the

indicated end of the wire bundle. Plug the other end
into an outlet.

WARNING: Keep hands and fingers clear of mov-
ing parts.

37

83

Wires

64

16

26

Lubricate