MACHINE-TROUBLESHOOTING
86292490 VOYAGER DUO 08/20/07
4-23
PROBLEM
CAUSE
SOLUTION
Battery disconnected
Check all battery cable connections
Battery cables corroded
Clean connections
No power to machine
Faulty key switch
Replace switch
Low battery charge
Charge batteries
Machine turned on with propel
trigger not in neutral position
Allow pedal to return to neutral.
Restart
Tripped circuit breaker
Reset circuit breaker and check brush
Controller overheated
Allow cool down period
Loose motor connection
Check wires and connections from
controller to motor
Faulty throttle circuit or
potentiometer
Check wires and connections from throttle
to controller and potentiometer resistance
Little or no propel
Faulty brake circuit
Check wires connections
Machine does not change
speeds
Faulty speed control circuit or
potentiometer
Check wires, connections and pot
Forward speed only
Reverse speed only
Faulty forward/reverse switch
Replace switch
Debris caught in scrub brushes
Remove debris
Low scrub brush down pressure
Check brush wear
Poor scrubbing
performance
Low battery charge
Charge batteries
Solution tank empty
Fill solution tank
Solution pump turned off
Turn on pump
Solution strainer plugged
Clean solution strainer
Solution system plumbing
obstructed
Clear obstruction from plumbing
Pump obstructed
Clean or replace pump
Solution solenoid valve obstructed
or stuck
Clean or replace valve
Jet(s) obstructed
Clean or replace jet(s)
Faulty pump circuit or pump
Check wiring, connections, and pump.
Little or no solution flow to
the floor
Faulty solenoid
Check solenoid valve
Circuit breaker(s) tripped
Reset circuit beaker(s) and check brush
pressure.
Low battery charge
Charge battery
Fault brush circuit or motor
Check wires, connections and motor
Brush motors do not run, or
run slowly
Worn brush motor brushes
Replace brushes, check commutator
Actuator circuit breaker tripped
Reset breaker
Scrub deck will not go
down/up
Faulty actuator circuit or actuator
Check wires, connections and actuator
No chemical flow (Deluxe)
Tank(s) empty
Fill with prime chemicals
Chemical pump not primed
Prime chemical pump
Chemical system obstruction
Rinse system with water