MAINTENANCE-SOLUTION STRAINER & PUMP - DELUXE

86292490 VOYAGER DUO 08/20/07

4-14


1. SOLUTION

STRAINER

The solution strainer is located under the
recovery tank. The strainer protects the pump,
solenoid valve and jets from debris. If there is
little or no solution flow to the ground, check the
strainer for debris. Clean the solution strainer.
To remove the strainer, turn the bottom part of
the strainer counterclockwise until the bottom is
separated. Clean out the debris from the wire
mesh and the bowl and re-assemble. Make
sure the O-ring gasket is in place when re-
assembled.

2. PUMP

The pump is located on underside of the
recovery tank. The pump delivers solution from
the tank to the scrub deck.

To repair or replace pump:

1.

Remove bracket assembly from the bottom
side of the recovery tank.

2.

Remove hoses connecting the pump.

3.

Remove screws that secures pump to
mounting plate.

3. SOLENOID

VALVE

The solenoid valves are mounted on the front of
the scrub deck, on left side.

The solenoid valves shuts off solution flow to
jets whenever scrubbing stops or in reverse. To
repair or replace solenoid valve, remove screws
that secure it to deck.



















4. JETS


The two sets of jets are located in front of the
scrub deck.

The jets spray cleaning solution onto the carpet.
The spray pattern should be checked regularly
and if jets become clogged they should be
cleaned or replaced immediately.

To clean jets:

1. Remove jet from jet body by rotating it

counterclockwise.


2. Blow debris back through orifice if possible.

Do not use pointed object to unplug jet. This
will damage jet and cause improper spray
pattern and solution flow through jets.


3. If jet cannot be cleaned by blowing debris

back through its orifice, submerge jet in
small container of acetic acid and let soak
for up to six hours.


4. After soaking jet, use a soft brush to remove

debris and rinse thoroughly.


5. Install jet in jet body by rotating it clockwise

firmly into place.

6. For lower flow in extraction “B” other jets are

available. (See Accessories page).