beautypg.com

629-249-0 - pg4-8 and 4-9, Maintenance-scrub deck – Windsor VOYDU1 User Manual

Page 31

background image

MAINTENANCE-SCRUB DECK

86292490 VOYAGER DUO 08/20/07

4-8

Do not use a pressure
washer to clean around

the brush motors. Use tap pressure only.

TO REPLACE SCRUB BRUSH MOTORS

1. With the scrub deck in the lowered position,

remove the deck cover and disconnect brush
motor wiring connector from harness.


2. Remove the motor and end bracket assembly

from the deck.


3. Separate brush motor from end brackets.

4. Reverse to reassemble.












































BRUSH MOTOR CARBON BRUSH
REPLACEMENT

1.
Scribe alignment mark on motor barrel to motor

cap. Remove two bolts.


2. Remove end cap from motor.

NOTE: Motors contain two wave washers in
cap. Do not lose these.

3. Release brush from spring tension. Remove

screw connecting brush wire lead to brush
holder. Clean brush holder to insure free
movement.


4. Retract spring and install new brush. Install

connector screw and lead.


5. When all new brushes are installed. Place all in

retracted position, held into brush holder by
spring tension.


6. Carefully place end cap onto bearing on motor

shaft.
NOTE: Use care to assure wave washer
alignment.

7. With end cap in partially installed position,

release all brushes to contact position with
motor commutator.

NOTE: Failure to insure all brushes are released
will result in motor failure.

8. Reset end cap and realign with scribe marks on

motor barrel. Reinstall the two attach bolts from
cap into base.


9. Maintain alignment between motor barrel base

and cap.