beautypg.com

86309580p4-2, Machine troubleshooting – Windsor Floor Polisher SP17IE-10090270 User Manual

Page 16

background image

MACHINE TROUBLESHOOTING

86309580 FLOOR POLISHER 10/08/08

4-2

PROBLEM CAUSE

SOLUTION

Machine will not run

Circuit breaker tripped in
building.

Check and reset.

Power switch failure

Test switch for continuity and
replace if necessary.

Tripped circuit breaker

Reset.

Faulty power cord

Replace.

Fuse in motor blown
(Dual speed only)

Replace
CAUTION: To reduce the risk
of electrical shock, unplug the
machine before opening fuse
holder. Fuse will only open
under extreme conditions.
Investigate cause before
replacing.

Electrical shock

Equipment not grounded

Follow grounding instructions
exactly.

Receptacle not grounded

Have an electrician inspects
building’s wiring.

Internal wiring problem

Ensure that the machine wiring
matches the appropriate wiring
diagram. Replace any wires or
components that are short
circuiting.

Repeated circuit breaker
tripping

Mechanical problem

Higher amp draws indicate a
mechanical problem. Find the
problem before using the
machine.

Faulty circuit breaker

Test circuit for continuity.
Replace circuit breaker if
necessary.

Excessive vibration

Pad not centered

Re-center pad.

Damaged or unevenly worn
pad

Replace pad. Do not rest
machine on pad when not in
use.

Damaged pad driver

Replace.

Pad does not turn but motor is
running

Sheer coupling has failed

Replace coupling.