MACHINE TROUBLESHOOTING
86309580 FLOOR POLISHER 10/08/08
4-2
PROBLEM CAUSE
SOLUTION
Machine will not run
Circuit breaker tripped in
building.
Check and reset.
Power switch failure
Test switch for continuity and
replace if necessary.
Tripped circuit breaker
Reset.
Faulty power cord
Replace.
Fuse in motor blown
(Dual speed only)
Replace
CAUTION: To reduce the risk
of electrical shock, unplug the
machine before opening fuse
holder. Fuse will only open
under extreme conditions.
Investigate cause before
replacing.
Electrical shock
Equipment not grounded
Follow grounding instructions
exactly.
Receptacle not grounded
Have an electrician inspects
building’s wiring.
Internal wiring problem
Ensure that the machine wiring
matches the appropriate wiring
diagram. Replace any wires or
components that are short
circuiting.
Repeated circuit breaker
tripping
Mechanical problem
Higher amp draws indicate a
mechanical problem. Find the
problem before using the
machine.
Faulty circuit breaker
Test circuit for continuity.
Replace circuit breaker if
necessary.
Excessive vibration
Pad not centered
Re-center pad.
Damaged or unevenly worn
pad
Replace pad. Do not rest
machine on pad when not in
use.
Damaged pad driver
Replace.
Pad does not turn but motor is
running
Sheer coupling has failed
Replace coupling.
- SP1 Floor Polisher SP13-10090220 Floor Polisher SP20X-10090320 Floor Polisher SPT20X-10090380 Floor Polisher UDS20-10090630 Floor Polisher U20X-10090610 Floor Polisher SP17IA-10090260 SP17XIE-10090300 Floor Polisher SPDS20-10090350 Floor Polisher U20-10090600 Floor Polisher U17-10090580 U20X-10090630 Floor Polisher SP17-10090240 Floor Polisher U17X-10090590 Floor Polisher SP17X-10090280 Floor Polisher SP20-10090310 Floor Polisher SP15-10090230 U17-10090580 Floor Polisher SPT17-10090370