beautypg.com

White Rodgers 1F94W-71 User Manual

Page 16

background image

16

AUDIO PROMPTING — Each time you

press a button, the thermostat will beep (this
feature works only when the thermostat is
attached to the wall and 24 VAC power is
present to the thermostat).

BACKLIT DISPLAY — When you press

any button on the thermostat, the display is
lit for approximately eight seconds (this fea-
ture works only when the thermostat is
attached to the wall and 24 VAC power is
present to the thermostat).

SYSTEM INDICATOR LIGHTS — The four

lights on the upper right part of the thermo-
stat indicate system operation (see PARTS
OF THE THERMOSTAT
).

COMPRESSOR SHORT CYCLE PROTEC-

TION — To protect your compressor from
potential damage due to rapid cycling, this
thermostat has a built-in delay of 5 minutes

between heat pump heating and cooling
cycles. The following may cause a time
delay in COOL:

a) Return of power after a power outage.

b) Pressing

SYSTEM

HEAT/EMER/OFF/

COOL/AUTO

to change operating

modes.

c) Pressing

or

, creating a call

for HEAT or COOL too soon after a
previous call.

COMPRESSOR LONG TERM CYCLE

PROTECTION — If your system begins to
operate too soon after an extended power
outage, the compressor may be damaged
due to crankcase oil temperature change.
This thermostat has a built-in time delay of
one hour less than the length of the power
loss (up to 12 hours). When power is re-
stored to the system, heaters in the system