beautypg.com

Technical service, Specifications service hints, Wiring diagram – Vanguard Heating VS24PR User Manual

Page 26

background image

26

103448

18" Variable

24" Variable

30" Variable

Btu (Variable)

16,000/26,000

20,000/33,000

21,500/36,000

Type Gas

Propane Only

Propane Only

Propane Only

Ignition

Piezo

Piezo

Piezo

Pressure Manifold

7.9" W.C.

7.9" W.C.

7.9" W.C.

Inlet Gas
Pressure (in. of water)

Maximum

14"

14"

14"

Minimum*

11"

11"

11"

* For purpose of input adjustment

Shipping Weight

32 lbs.

34 lbs.

36 lbs.

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA
International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

SPECIFICATIONS

SERVICE HINTS

When gas pressure is too low

• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane (LP) gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane (LP) gas
supplier.

WIRING

DIAGRAM

Switch

White

On
Off

Auto

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

This manual is related to the following products: