beautypg.com

Installing, Warning, Caution – Vanguard Heating VS24PR User Manual

Page 12: Continued

background image

12

103448

14"
Min.

Combustible
Material

Non-Combustible
Material

Hearth

5"
Min.

Combustible
Material

INSTALLING

Continued

Floor Clearances

A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combus-

tibles (see Figure 8).

Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level

B. If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above

the combustible flooring (see Figure 9).

Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring

INSTALLING HEATER BASE ASSEMBLY

WARNING

You must secure this heater to fireplace floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak.

WARNING

If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor
to allow access to heater control panel. This will insure adequate air flow and guard against
sooting. Raise fireplace floor with non-combustible material. Make sure material is secure.

CAUTION

Do not pick up heater base assembly by burners. This could damage heater. Only handle
base assembly by grates.

IMPORTANT:

Make sure the heater burners are level. If heater is not level, heater will not work properly.