9 Default Settings
7 8 5700/5800 GPS Receiver User Guide
5700 GPS Receiver Oper
ation
All 5700 receiver settings are stored in application files. The Default
application file, Default.cfg, is stored permanently in the receiver, and
contains the factory default settings for the 5700 receiver. Whenever
the receiver is reset to its factory defaults, the current settings (stored in
the Current application file, Current.cfg) are reset to the values in the
Default application file.
You cannot modify the Default application file. However, if there is a
Power Up application file (Power_Up.cfg) in the receiver, the settings in
this file can be applied immediately after the Default application file,
overriding the factory defaults.
For more information about application files, see Application Files,
page 52.
9.1
Default Settings
Table 9.1 shows the default settings for the 5700 receiver, as defined in
the default application file.
Table 9.1
Default settings
Function
Factory Default
SV Enable
All SVs enabled
General Controls:
Elevation mask
13°
SNR mask
7
RTK positioning mode
Low Latency
Motion
Kinematic
Power Output 3
Disabled
1PPS time tags
Off
ASCII time tags
Off
Serial Port 1:
Baud rate
38400
Format
8-None-1
Flow control
None