E6 level and blink codes, E6 l – True Fitness Z7 Series User Manual
Page 47

Z 7 Tr e a d m i l l O w n e r ' s G u i d e
63
C
AR
E
AND
M
AIN
TENANC
E
The failure code displayed will be “E-5 Sensor” when receiving the E5 Sen-
sor error, enter diagnostic mode and check the error log. Below is a list of
status display codes. When the drive is faulted, the Status LED blinks out
the default code. The code will blink the proper number of times, pause
with the LED off, and then repeat the code.
STATUS CODE
DESCRIPTION
IMPLICATION
No Blink (Steady On)
No Faults
Running
Fast (Steady Blink)
No Faults
Ready
LED Off
AC Line Power
Insufficient
No or Low Voltage
1 Blink (E601)
100% Command
Runaway Command
2 Blink (E602)
Sensor Feedback Error
Sensor Error
3 Blink (E603)
Voltage Trip Error
Motor Issue
4 Blink (E604)
Output Over Current
High Motor Current
5 Blink (E605)
Control Supply Under
Voltage
Inadequate Power Line
6 Blink (E606)
Drive Over Temperature MCB Over Tempera-
ture
7 Blink (E607)
AC Over Voltage
Line Voltage Too High
8 Blink (E608)
Output Short Circuit
Short Circuit to Motor
E6 Level and Blink Codes
C
ARE
AND
M
AINTENANCE
E6 L
EVEL
AND
B
LINK
C
ODES