beautypg.com

Replacing the fuser cleaning roller – Tally Genicom Tally Colour Laser T8006e User Manual

Page 74

background image

Tally T8006e Color Laser Printers User Guide

66

Replacing the Fuser Cleaning Roller

Replace the fuser cleaning roller at least once every 12 months, or when

the control panel display indicates that replacement is necessary. The life

of the fuser cleaning roller in the T8006e is about 12,000 pages (at a 5%

toner coverage rate on letter-size paper).

Warning!

Make sure the power switch is off, and that the printer has

cooled for a minimum of 30 minutes before replacing supplies near the fusing

unit.

Caution!

Always replace the ozone filter when you replace the fuser

cleaning roller.

8. Install the new waste toner pack.

9. Close the front cover by carefully push-

ing it inward until it locks.

1. Turn off the power switch.