Technical specifications, Power requirements, Table 2: mcu ratings – TANDBERG Codian HD MCU 4500 Series User Manual
Page 18: Over-current protection, Operating environment, Table 3: operating environment, Anti-static precautions, Technical specifications anti-static precautions

14
Technical specifications
Power requirements
Over-current protection
Ensure the supply to this unit is protected by a branch circuit protector rated by a
maximum of 20A.
Operating environment
The MCU must only be used within the following environmental conditions:
Anti-static precautions
When servicing or removing components or connections, first attach an anti-static
wrist strap to an appropriate earth point.
Table 2: MCU ratings
Rating
Value
Nominal voltage
115V to 230V 50/60 Hz
Current rating
6A Maximum
Supply voltage range
100 to 240V 50/60 Hz
Caution — over-current devices must meet applicable national and local
electrical safety codes and be approved for the intended application.
Table 3: Operating environment
Environment
Temperature
Humidity
Operating environment
0°C to 35°C
10% to 95%
(non-condensing)
Non-operating environment
-10°C to 60°C
10% to 95%
(non-condensing)
Optimum operating environment
21°C to 23°C
45% to 50%
(non condensing)
!