5 scan lockout mode, 6 data lockout mode – Tyco Electronics MM23772 User Manual
Page 76

MM23772, Rev. B
76
8.29.5
Scan Lockout Mode
Following the transmission or reception of a data call, if scan is enabled, scanning will stop temporarily
(two independent pre-programmed times; after a receive data call and after a transmit data call). During
this time the scan indicator will flash to indicate that scan is enabled but temporarily suspended. This
mode is normally exited when the pre-programmed time expires; however, the following actions will
terminate the scan lockout mode before the timeout is completed:
•
The CLEAR button is pressed. The PTT is pressed.
•
The group or system is changed.
•
Phone call mode is entered.
•
Individual call mode is entered.
•
A new emergency assignment has been received.
•
An emergency is declared or cleared.
•
An individual or phone call is received.
•
An Agency, Fleet or System All Call is received.
•
or
is pressed to toggle Scan ON or OFF.
8.29.6
Data Lockout Mode
During the voice call scan hang time (pre-programmed) the radio will not receive data calls.