Electrical supply, Figure 4: wall connection, Step 3: unpacking and moving the range – Thermador PRO GRAND PRD48 User Manual
Page 10: Caution
English 8
Electrical Supply
Installation of the range must be planned so that the rough-
in of the terminal block for the receptacle or conduit
connection will allow maximum clearance to the rear of the
unit.
When the power supply cord or conduit is connected to the
mating receptacle or terminal block cover, the combined
connection should protrude no more than 2“(51mm) from
the rear wall (see Figure 4).
Refer to Figure 11 on page 16 for location of the terminal
block on unit. To minimize binding when the unit is
connected, orient the receptacle or conduit connector, and
slide back into position.
Step 3: Unpacking and Moving
the Range
CAUTION:
The unit is heavy and should be handled
accordingly. Proper safety equipment such as
gloves and adequate manpower of at least two
people must be used in moving the range to
avoid injury and to avoid damage to the unit or
the floor. Rings, watches, and any other loose
items that may damage the unit or otherwise
might become entangled with the unit should be
removed.
Hidden surfaces may have sharp edges. Use
caution when reaching behind or under
appliance.
The range has an approximate shipping weight as shown in
“Chart A”. The grates, griddle plate, burner caps, and oven
racks must be removed to facilitate handling. Do not
remove the griddle element and tray assembly.
1. Remove the outer carton and packing materials from
the shipping pallet but leave the adhesive-backed foam
layer over brushed-metal surfaces, to protect finish
from scratches, until the range is installed in its final
position.
2. Remove the door(s) (see “Step 4: Door Removal and
Reinstallation” on page 10); however, do not remove
the warming drawer or steam oven doors. This will
create an estimated reduction in the weight as shown
in “Chart A” and allow the range to pass through 30"
(762mm) doorways (see clearances shown on page 6).
Caution
DO NOT lift the range by the oven door's handle,
as this may damage the door hinges and cause
the door to fit incorrectly.
Figure 4:
Wall Connection
2” (51mm) maximum
when plugged in
2” (51mm)
maximum
Chart A
36"
Range
48"
Range
Shipping Weight
420 lbs
(191 kg)
590 lbs
(268 kg)
Weight without packing
materials
360 lbs
(163 kg)
530 lbs
(240 kg)
Without door(s), burner caps,
and oven racks
260 lbs
(118 kg)
390 lbs
(177 kg)