Symptom:

In all four colors?

Solution: 1)

Choice of media or

2)

Replace Imaging Unit, or Fuser, or Fuser Roll or Main Charge Grid.

Pieces of the printed image are
missing and reappear out of place,
approximately 129 mm (5 in.) down
the page.

or

Media frequently wraps around
the Fuser (

Jam at C

).

Hints

Use Tektronix media.

Print 10-20 blank pages of

plain

paper.

To avoid jams with Tektronix transparencies, make sure that the logo strip is

loaded

face-down

for the Multi-Purpose Tray and

face-up

for the transparency

tray.

If

Jam at C

, clear the media jam.

Print 10-20 blank pages to clean
the roller.

If you still see the problem,

replace the Fuser Roll.

If you still see the problem,

replace the Fuser.