Peripheral Equipment

209

DVI-D cables transmit digital T.M.D.S. signals, DVI-A cables transmit analog VGA signals and
DVI-I cables can transmit either digital or analog signals.

It is possible to extend existing DVI cables by the use of extension cables. The maximum cable
length however, is 5 meters. Going beyond that may result in quality loss.

DVI-I - Combined Analog and Digital Connector Pin Assignments:

Pin

Signal
Assignment

Pin

Signal
Assignment

Pin

Signal
Assignment

1

T.M.D.S.
Data2-

9

T.M.D.S.
Data1-

17

T.M.D.S. Data0-

2

T.M.D.S.
Data2+

10

T.M.D.S.
Data1+

18

T.M.D.S. Data0+

3

T.M.D.S.
Data2/4 Shield

11

T.M.D.S.
Data1/3 Shield

19

T.M.D.S.
Data0/5 Shield

4

T.M.D.S.
Data4-

12

T.M.D.S.
Data3-

20

T.M.D.S. Data5-

5

T.M.D.S.
Data4+

13

T.M.D.S.
Data3+

21

T.M.D.S. Data5+

6

DDC Clock

14

+5V Power

22

T.M.D.S. Clock
Shield

7

DDC Data

15

Ground (return
for +5V, HSync
and VSync)

23

T.M.D.S. Clock+

8

Analog Vertical
Sync

16

Hot Plug Detect

24

T.M.D.S. Clock-

C1

Analog Red

C2

Analog Green

C3

Analog Blue

C4

Analog
Horizontal
Sync

C5

Analog Ground
(analog, R, G &
B return)

5.1.2

Audio

6 Audio Inputs:

3 microphone inputs (balanced, 24V phantom powered) via XLR connectors.

3 audio inputs (line level) via RCA connectors.



All audio inputs are active by default. For further information, refer to chapter

Audio

.


Audio input connector specification:

Connector label

Microphone(s)

Audio input(s)

Signal type

Balanced

Unbalanced

Connector (codec)

XLR-F, pin 1-gnd,
pin 2 hot, pin 3-
cold/neutral

Female RCA/phono,
sleeve-ground,
centre-signal

Input impedance

2400 ohms (pin 2 -
3)

10K ohms

Max input level when

83 mVpp