16. ERROR MESSAGE TABLE

16. ERROR MESSAGE TABLE

16- 3

CMT Operation Mode

LON System Mode

M: Master scale

BM: Backup master scale S: Satellite scale

Message

Cause

Solution

Mismatch of the model type.

Mismatch of the base unit.

Mismatch of the VERSION.

Mismatch of the
TRANSMITTING DATA.

MISMATCH SCALE SPEC

Mismatch of the scale capacity.

Press the

key.

Parity error

Framing error

Overrun error

Data error

BAD TAPE OR CMT

Two or More Hardware error

Press the

key.

TIME OUT ERROR

Time out error

Press the

key.

Error message

Cause

Solution

M

BM/S

COMMUNICATION
ERROR

1.

The power of the master or
backup master scale is not
turned ON.
They are not connected with
each other or in off-line state.

2.

LON cable is broken.

1.

Turn the power of the master

or backup master scale ON.

Connect them with each

other or turn the scale in-line.

2.

Call your authorized service

representative.

SEQUENCE ERROR

The power was not turned OFF and
ON again after setting ID #.

Turn the power switch OFF and
ON again.

SEQUENCE NO.
ERROR

Text data number is incorrect.

Call your authorized service
representative.

MASTER BUSY

Registration job is performed on a
satellite scale while reset job is
performed on the master scale.

1.

Quit reset job on the master
scale.

2.

Quit registration job on the
satellite scale.

BACKUP MASTER
NOT RESET

The backup master does not have
same PLU with the master scale.

Down load PLU from the master
to the backup master scale.
Then run the reset operation
again.

TEXT ERROR ##

1.

Error text is found.
02: Sequence No. error
05: LRC error
08: Text error
09: Command error

2.

The master scale differs from
other scale in ROM version.

Call your authorized service
representative.

CLEAR