9

D4133738B

(3)Restart / Reset

Restart / reset available via ext. VD signal

(Switching via rear panel DIP SW, Initial OFF)

Notes : * The exposure-time (shutter-speed) is determined by ext.

VD interval.

** Enabled when rear-panel DIP SW OFF.

***Provide Consecutive HD.

[Partial scan]

(1)Operation mode







Note: Items shown as [Option] in this document is not included in your purchase as

standard components. Contact our dealer / distributor for details.

(2) Reset mode

As shown in (1) above, non-reset and V-reset is available.

([Option]: Doesn’t come as standard. Contact our dealer / distributor for details)

(a) non-reset (Electronic shutter enabled)

VD doesn’t get reset after video readout. The interval of VD signal is as follows.

*Note: Under normal shutter mode, when non-reset is selected on partial scan,

electronic shutter is valid.

Please note that the exposure time is shortened than the setting value

when the external VD is input at shorter than the above VD interval.

(b) V-reset (Electronic shutter disabled)

VD does get reset after video readout. Under internal sync, the interval of VD signal is as

follows.





Note: Items shown as [Option] in this document is not included in your purchase as standard

components. Contact our dealer / distributor for details.

No

Scan mode

Sync

Reset

E-shutter Normal

E-shutter RTS

1

Non-reset Enabled [Option]

Enabled

2

V-reset

Disabled

3

Consecutive HD VD IN Non-reset Enabled [Option]

Enabled

4

Consecutive HD (VD) IN

V-reset

Disabled

5

Non-reset Enabled [Option]

Enabled

6

V-reset

Disabled

7

Consecutive HD VD IN Non-reset Enabled [Option]

Enabled

8

Consecutive HD (VD) IN

V-reset

Disabled

Internal

1/2 partial

1/4 partial

Internal

1/2 partial scan 1/4 partial scan

796H

796H

VIDEO OUT

Partial A

Partial B

Partial C

VD Interval

1/2 partial scan 1/4 partial scan

387H

193H

VIDEO OUT

Partial A

Partial B

Partial C

Partial E

Partial D

VD interval