Output Volt Amp Capacity
(VA)

1200

Output kVA capacity (kVA)

1.2

Output Watt Capacity
(watts)

940

Nominal Output Voltage(s)
Supported

115V; 120V

Frequency compatibility

60 Hz

Output voltage regulation
(line mode)

-18%, +8%

Output voltage regulation
(Battery mode)

115V (+/- 5%)

Built-in UPS output
receptacles

6 5-15R outlet(s)

Output AC waveform (AC
mode)

Sine wave

Output AC waveform
(battery mode)

PWM sine wave

INPUT

Rated input current (at
maximum load)

8.25A

Nominal Input Voltage(s)
Supported

120V AC

UPS input connection type

5-15P

UPS Input cord length (ft.)

6

UPS Input cord length (m)

1.8

Recommended Electrical
Service

15A 120V

BATTERY

Full load runtime (minutes)

7 min. (940w)

Half load runtime (minutes)

16 min. (470w)

DC system voltage (VDC)

36

Battery recharge rate
(included batteries)

Less than 8 hours from 10% to 90%

Replacement battery
cartridge (internal UPS
battery replacement)

RBC53

Battery Access

Battery access door

VOLTAGE REGULATION

Voltage regulation
description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147

Overvoltage correction

Input voltages between 128 and 147 are reduced by 12%

Undervoltage correction

Input voltages between 93 and 107 are boosted by 14%