beautypg.com

Tripp Lite UT3012UL User Manual

Specifications, Warranty registration, Minimum recommended cable sizing chart

background image

Inverter DC Volt: 12

Wire Gauge

Twin 00 (2/0)

Watts

6

4

2

0

00 (2/0)

(UT3012UL only)

500

15 ft

25 ft

39 ft

62 ft

79 ft

158 ft

700

11 ft

18 ft

28 ft

44 ft

56 ft

112 ft

1000

N/R

12 ft

20 ft

31 ft

39 ft

78 ft

2000

N/R

N/R

N/R

16 ft

20 ft

40 ft

3000

N/R

N/R

N/R

10 ft.

13 ft.

26 ft

N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the

shorter the cable, the better the performance)

Note on Labeling

Two symbols are used on the RV labels.

V~

: AC Voltage

V

: DC Voltage

Minimum Recommended Cable Sizing Chart

Use in conjunction with DC wiring connection instructions in the Battery Connection section.

Specifications

MODEL NUMBER:

UT750UL

UT1250UL

UT2012UL

UT3012UL

Series Number:

AGAP5088

AGAP5217

AGAP5290

AGAP4669

Agency Approvals:

cTUVus

cTUVus

cULus

cULus

AC Input Connection (for optional charging):

Input Cord

Input Cord

Input Cord

Hardwire AC Input

AC Output Connection:

Two GFCI Outlets

Two GFCI Outlets

Two GFCI Outlets

Hardwire AC Output

INVERTER

Continuous Power (@ 20 C):

750

1250

2000

3000

OverPower™ Peak Surge Power:*

1125

1875

3000

4500

Double Boost™ Peak Surge Power:*

1500

2500

4000

6000

Maximum Output AC Current (Continuous):

6.3 A

10.4 A

16.7 A

25 A

UL-Recognized DC Fuse Required:

One 80 A

One 200 A

Two 200 A

Two 275 A

DC Input Current @ Nominal V DC Full Load:

72 A

127 A

190 A

290 A

DC Input Volts (Nominal):

12 VDC

12 VDC

12 VDC

12 VDC

DC Input Voltage Range:

10-15 VDC

10-15 VDC

10-15 VDC

10-15 VDC

Output Volts (Nominal):

120 VAC, ± 5%

120 VAC, ± 5%

120 VAC, ± 5%

120 VAC, ± 5%

Output Frequency (Nominal):

60 Hz, ± 0.5 %

60 Hz, ± 0.5 %

60 Hz, ± 0.5%

60 Hz, ± 0.5%

Efficiency:

88% to 94%, depending on

88% to 94%, depending on

88% to 94%, depending on

99% to 94%, depending on

load and temperature

load and temperature

load and temperature

load and temperature

BATTERY CHARGER

Charging Capacity DC:

Selectable 45 A** / 11 A

Selectable 40 A** / 10 A

Selectable 60 A** / 15 A

Selectable 140 A** / 35 A

Input Current AC:

9.3 A

8.2 A

12 A

30 A

Acceptance Volts VDC:

Selectable 14.4V** /

Selectable 14.4V** /

Selectable 14.4 V** /

Selectable 14.4 V** /

14.2 V Wet** / Gel

14.2 V Wet** / Gel

14.2 V Wet** / Gel

14.2 V Wet** / Gel

Float Volts DC (Wet/Gel):

13.3 V (13.6 V)

13.3 V (13.6 V)

13.3 V (13.6 V)

13.3 V (13.6 V)

Input Volts (Nominal):

120 VAC

120 VAC

120 VAC

120 VAC

* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice. This
product designed and engineered in the USA.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number
can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this
product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.

1111 W. 35th Street Chicago, IL 60609 • (773) 869-1234 • www.tripplite.com

Copyright © 2005 Tripp Lite. All rights reserved.

200511035 93-2512

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty today to register the warranty for
your new Tripp Lite product. You'll be automatically entered into a
drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

WARRANTY REGISTRATION:

register online today for a chance to win a FREE Tripp Lite product—www.tripplite.com/warranty