beautypg.com

Ad535_config, Ad553_freemcbsp – Texas Instruments TMS320C6000 User Manual

Page 18

background image

AD535_config

2-6

Description

This is the AD535 configuration structure used to set up a codec channel.
You create and initialize this structure and then pass its address to the

AD535_config()

function.

Example

AD535_Config myConfig = {
AD535_LOOPBACK_DISABLE,
AD535_MICGAIN_OFF,
AD535_GAIN_0DB,
AD535_GAIN_0DB
};
AD535_config(hAD535,&myConfig);

Sets up AD535 using configuration structure

AD535_config

Function

Void AD535_config(
AD535_Handle hAD535,
AD535_Config *config
);

Arguments

hAD535

Handle to codec channel, see

AD535_open()

Config

Pointer to an initialized configuration structure, see

AD535_Config

Return Value

none

Description

Sets up the AD535 using the configuration structure. The values of the
structure are written to the AD535 control registers.

Example

AD535_Config myConfig = {
AD535_LOOPBACK_DISABLE,
AD535_MICGAIN_OFF,
AD535_GAIN_0DB,
AD535_GAIN_0DB
};
AD535_config(hAD535,&myConfig);

Sets the FREE bit of an McBSP serial port to 1

AD553_freeMcbsp

Function

Void AD535_freeMcbsp(
int port
)

Arguments

port

McBSP port: MCBSP_DEV0, MCBSP_DEV1

Return Value

none