beautypg.com

Configurable backup, Active backuptm mode (optional), Datasync mode – Texas Memory Systems 325 User Manual

Page 9: Mirror mode, None (volatile) mode, 5 configurable backup

background image

failure occurs, the RamSan-320/325 contains redundant batteries. When
fully functional and fully charged, the batteries are able to provide at least

30 minutes of operation.

The system monitors the internal disks and batteries for a failure
condition. In such an event, it notifies the operator of an error through

the front panel display and the management software.

1.5 Configurable Backup

The RamSan-320/325 allows the administrator to set backup modes for
each LUN individually or system wide.

Active Backup

TM

mode (optional)

This ideal mode for most users is only available from Texas Memory

Systems. In Active Backup mode, the RamSan uses available internal
bandwidth (i.e. performance not utilized by the applications) to constantly

backup memory to the disks. The system automatically optimizes this
operation to backup the maximum amount of data at any given time

without impacting performance. This means that at any one time, most of
the data already resides on disk. Upon emergency or shutdown, the unit
need only finish the backup that is already nearly completed. Active

Backup is an optional feature on the RamSan-320/325; therefore, some
systems may not display this option.

Datasync mode

In DataSync mode, reads and writes are done only to memory. The disks
remain offline during normal operation. If power loss occurs and the

shutdown timer reaches zero, or the user requests a shutdown, the
system takes the Fibre Channel interfaces offline and synchronizes all data
to the internal hard drives.


Mirror mode

This operational mode provides the highest level of data integrity. The

system mirrors all write operations to the internal hard drives and
memory. The system performs read operations from memory only. This

mode allows read intensive applications to benefit from high speed reads
while ensuring that any data written to the RamSan is simultaneously

written to non-volatile storage.


None (Volatile) mode

This operational mode disables the backup functionality for the LUN
making it completely volatile. In the case of system shutdown or failure,

all data stored in the selected LUN will be lost intentionally.

RamSan-300/320/325 User’s Manual

- 5 -

This manual is related to the following products: