Texas Memory Systems 325 User Manual
Page 122

Name array-state-notif
Description The disk array state has changed
Includes
Message
Name fc-state-notif
Description A fibre channel controller state has changed
Includes
Message
Device Number
Disk State:
-1 notImplemented This indicates there may be an SNMP reporting
problem
0 noState
N/A
1 error
N/A
2 warn
N/A
3 good
The FC controller is working properly.
4 warnHigh
The FC controller has detected some type of error;
possibilities include: RX errors, CRC errors, and
corrected ECC errors.
5 errorHigh
The FC controller is not functioning correctly; the
controller has failed or detected uncorrected ECC
errors.
6 noDevice
N/A
7 notMonitored
N/A
Name lun-change-notif
Description The LUN table has changed
Includes
Message
Name fc-config-change-notif
Description The configuration of a fibre channel controller has changed
Includes
Message
Device Number
Name system-message-notif
Description A system message
Includes
Message
RamSan-300/320/325 User’s Manual
- 118 -