A example lun configuration, 1 a example lun configuration – Texas Memory Systems 325 User Manual
Page 71

6.1 A Example LUN Configuration
This section summarizes how to change the system memory configuration
from the default factory configuration to a new configuration, which 
consists of four partitions and has access lists that allow only four host 
machines to use the RamSan. 
 
This demonstration assumes the four HBAs and the RamSan’s Fibre 
Channel ports are attached to the same fabric. In addition, this system 
has 16 Gigabytes of memory. 
 
The new configuration consists of four partitions that HBAs access using 
four Fibre Channel ports in the RamSan. This demonstration assigns each 
HBA a unique LUN. The example results in the following configuration: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6-2: Reconfigured LUN Mapping
To change from the default configuration to the one described above, 
perform the following steps: 
2
Gigabytes
LUN 2
Port 2A
2
Gigabytes
LUN 3
Port 2B
6
Gigabytes
LUN 1
Port 1B
 
 
 
 
 
Fibre Channel
Ports
6
Gigabytes
LUN 0
Port 1A
HBA 1
HBA 2
HBA 3
HBA 4
•
Delete the default LUNs (see Section 6.8 )
•
Add two 6-Gigabyte LUNs (see Section 6.2 )
•
Add two 2-Gigabyte LUNs (see Section 6.2 )
•
Link each LUN to an Fibre Channel port (see Section 6.4 )
•
Add access lists (see Section 6.7 )
•
Set a backup mode for each LUN in a RamSan-320/325 (see Section
RamSan-300/320/325 User’s Manual
- 67 -