Assembly Section 2-8
ASSEMBLY
LOAD SENSE LINE INSTALLATION
To install the load sense lines from a Husco valve to the tractor remote valve, first
the existing load sense line located on the top of the tractor remote valve connecting
“load sense -1” and “load sense -2” must be removed, in order so that the two load
sense lines are able to be connected to the Husco valve. Next connect a 1/4” hose
(load sense - 1) to the tractor remote valve and to the top front port on the Husco valve.
Next connect a 1/4” (load sense - 2) to the tractor remote valve and to the port to the
lower right of the “load sense-1” line on the Husco valve.
For more information refer to the Parts Section pages for a complete diagram of
the tractor valve hookup.
2004 END CAP UPDATE
PRESSURE LINE INSTALLATION
The hydraulic pressure line will be plumbed into the rear of the tractor remote valve
end cap. Locate the pressure port on the end cap and remove the plug (refer to the
illustration below and the Parts Section pages for position of the pressure port). After
the plug is removed then install 22mm adapter. Next connect a 1/2” hose from the
tractor remote valve to the Tiger valve.
RETURN LINE INSTALLATION
The return line will be plumed in next to the pressure line in the tractor remote
valve end cap. Locate the return port and remove the plug (refer to the illustration
below and the Parts Section for the position of the return port). After the plug is
removed then install 22mm adapter or elbow. Next connect a 1/2” hose from the
tractor remote valve to the Tiger valve.
END CAP
PRESSURE
RETURN
LOAD SENSE